JORDI Test Facility

JORDI test facility

Technicians adjusting the JORDI facility. The large cylinder in the centre is the outer vacuum vessel of JORDI. © EPFL / Željko Gatarić

What We Test in JORDI

JORDI is a large cryostat, historically used for testing high-current leads – the components that bring current from room temperature to a cryogenic temperature of 4.5 K. Nowadays we use it for testing medium-size coils. Unlike SULTAN and EDIPO 2, there is no background field in JORDI, and the test objects are therefore tested only in their self-field. Its sample space, however, is significantly larger.

Key Parameters

ParameterValue
Background field0 T (test only in self-field)
Sample space
Sample currentUp to 10 kA
Cooling of the samplesupercritical He, 10 bar, up to 5 g/s
Temperature range5-10 K

Testing with us

JORDI is available for collaborative and contractual testing. Contact us if you are interested.

Two coils were tested recently:

  • The LASSO coil was manufactured in-house at SPC. It focused on testing quench detection in HTS conductors using temperature-based methods — optical fibres, co-wound superconducting wire and a thermocouple chain.
  • The JIANTS coil was the first test coil manufactured by Proxima Fusion. JIANTS’ primary objective was manufacturing R&D, and the testing of a novel quench-protection scheme called SCIPI, designed for non-insulated stellarator coils.