| Building volume X, Y, Z, (mm) | 240 x 240 x 240 |
| Recommended area for fine detail resolution | 220 x 220 x 240 |
| Build platform heating | 450°C |
| Laser source | Fiber Laser, max 400 W, adjustable |
| Laser wavelength | 1070 ±10 nm |
| Precision optics | Quartz F-Theta Lens |
| Laser spot diameter | 40 μm |
| Exposure speed | Up to 7000 mm/s |
| Typical layer thickness | 10 μm – 200 μm, adjustable |
| Powder bed layer monitoring | By CCD camera after recoating & after exposure |
| Melt pool monitoring | By photodiode @ Visible and NIR |
| Other monitoring | Laser power, temperature, humidity, pressure |
| Inert gas | Nitrogen, Argon |
| N2 chamber flooding vol | 300 l |
| Inert gas consumption N2 | 20 l/min @ 1,5% O2 |
| Ar chamber flooding vol | 750 l |
| Inert gas consumption Ar | 50 l/min @ 0.1% O2 |